Kalashnikov A.A. Abstract. This paper is devoted to increase of reliability and accuracy of the level measuring at NPP technological vessels. It proposes the diagnostic method of level measuring channels which allows to reveal the random measurement error including the cases where no redundant level measurement channels within the APCS. It is achieved by comparing the calibration characteristics of the channel taken in on-line or in a certain cutoff time with the reference characteristics obtained beforehand in the period when the measuring channel was serviceable. Mathematical procedures are proposed here for diagnostic implementation can be considered in the future design of an expert system of on-line monitoring of the level measuring channels in the NPP technological vessels. Keywords: NPP, APCS, level measuring by hydrostatic method, on-line monitoring of level measuring channels.
А. A. Kalashnikov (Lead Engineer, Atomtechenergo Corporation, Moscow, Russia) E-mail: Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра.
1. Kalashnikov A. A. (2016). On-line monitoring of the level measuring channels with differential pressure sensors at the NPP. Part 1. Mathematical model of a reference sensor. Kontrol'. Diagnostika, (4), pp. 40-46. doi: 10.14489/td.2016.04. pp.040-046.
This article is available in electronic format (PDF). The cost of a single article is 350 rubles. (including VAT 18%). After you place an order within a few days, you will receive following documents to your specified e-mail: account on payment and receipt to pay in the bank. After depositing your payment on our bank account we send you file of the article by e-mail. To order articles please fill out the form below:
|