Журнал Российского общества по неразрушающему контролю и технической диагностике
The journal of the Russian society for non-destructive testing and technical diagnostic
 
| Русский Русский | English English |
 
Главная Archive
22 | 12 | 2024
2021, 02 February

DOI: 10.14489/td.2021.02.pp.006-016

Danilov V. N.
ABOUT FEATURES OF CHARACTERISTICS OF A SIGNAL OF THE ANGLE BEAM PROBE WITH COMPOSITE PIEZOPLATE AND VARIOUS TYPES PIEZOELECTRIC CERAMICS
(pp. 6-16)

Abstract. On the basis of computer modelling spectra and pulses of signals of the combined angle beam probe with composite piezoplate with piezoelectric ceramics several types it is shown, that short pulses with the greatest amplitudes are provided with use in piezoplate segnetosoft ceramics (for example, types PZT-5H, APC-850). At use piezoelectric ceramics intermediate type (CTS-19) the maximal amplitude of a pulse of the angle beam probe with such piezoplate appears much less, than for segnetosoft ceramics. Application in composite piezoplate piezoelectric ceramics such as TKS-21 (with the increased anisotropy of factors of electromechanical coupling coefficients) is inexpedient because of small amplitude of a pulse.Use of polymeric matrixes with small wave resistance provides additional increase of amplitude and reduction of length of pulses of angle beam probes.

Keywords: composite piezoplate, angle beam probe, type piezoelectric ceramics, pulse of a signal, amplitude of a pulse, spectrum of a signal, wave resistance, width of a spectrum, polymeric matrix.

V. N. Danilov (JSC RPA “CNIITMASH”, Moscow, Russia) E-mail: Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра.  

 

1. Ermolov I. N., Lange Yu. V. (2006). Non-destructive testing: reference book: in 8 volumes. Vol. 3. Ultrasonic testing. 2nd ed. Moscow: Mashinostroenie. [in Russian language]
2. Danilov V. N., Ermolov I. N. (1999). Calculation of compositional piezoelectric transducers on a computer model. Defektoskopiya, (3), pp. 3 – 7. [in Russian language]
3. Danilov V. N., Ermolov I. N., Ushakov V. M. (1999). Transducer with composite piezoplate. Kontrol'. Diagnostika, (10), pp. 32 – 34. [in Russian language]
4. Danilov V. N. (2001). On the choice of materials for composite piezoplates. Defektoskopiya, (4), pp. 58 – 68. [in Russian language]
5. Ermolov I. N., Gitis M. B., Korolev M. V. et al. (1986). Ultrasonic transducers for non-destructive testing. Moscow: Mashinostroenie. [in Russian language]
6. Piezoelectric Ceramics: Principles and Applications. (2003). Minsk: FUAinform. [in Russian language]
7. Mezon U. (Ed.) Physical acoustics. Vol. 1. Methods and devices for ultrasonic research. Part A. Moscow: Mir. [in Russian language]
8. Teplyh A. A., Zaytsev B. D., Shihabudinov A. M., Borodina I. A. (2017). Refinement of the material constants of the TsTS-19 piezoceramic using an acoustic resonator in the form of a disk. Uchenye zapiski fizicheskogo fakul'teta MGU, (5), pp. 1751312-1 – 1751312-4. [in Russian language]
9. Danilov V. N., Artem'ev S. A., Zaharov A. F. (2007). Investigation of the operation of a model of a direct ultrasonic transducer for immersion and conventional control methods. Defektoskopiya, (6), pp. 3 – 19. [in Russian language]
10. Behrens E. (1967). Elastic Constants of Filamentary Composites with Rectangular Symmetry. Journal of the Acoustical Society of America, Vol. 42, (2), pp. 367 – 377.
11. Hayward G., Bennett J., Hamilton R. (1995). A theoretical study on the influence of some constituent material properties on the behavior 1-3 connectivity composite transducers. Journal of the Acoustical Society of America, Vol. 98, (4), pp. 2187 – 2196.
12. Danilov V. N. (2006). Program for computer simulation of the operation of electroacoustic paths of flaw detectors "IM-PULSE+". Defektoskopiya, (3), pp. 37 – 43. [in Russian language]
13. Danilov V. N. (1998). Calculation of the electroacoustic path of a flaw detector with a combined oblique transducer. Defektoskopiya, (8), pp. 20 – 27. [in Russian language]
14. Danilov V. N., Izofatova N. Yu., Voronkov V. A. (1997). Comparison of theoretical and experimental results of studying the operation of direct combined converters. Defektoskopiya, (6), pp. 39 – 49. [in Russian language]
15. Danilov V. N., Ermolov I. N., Shcherbakov A. A. (2003). Determination of the vibration frequency during ultrasonic testing. Defektoskopiya, (3), pp. 3 – 11. [in Russian language]

This article  is available in electronic format (PDF).

The cost of a single article is 450 rubles. (including VAT 18%). After you place an order within a few days, you will receive following documents to your specified e-mail: account on payment and receipt to pay in the bank.

After depositing your payment on our bank account we send you file of the article by e-mail.

To order articles please copy the article doi:

10.14489/td.2021.02.pp.006-016

and fill out the  form  

 

 

 
Search
Rambler's Top100 Яндекс цитирования