Danilov V. N.
STUDY OF THE PARAMETERS OF BOTTOM ECHO IN THE TRANSITION FIELD OF THE NORMAL PROBE
(pp. 4-11)

Abstract. By the method of computer simulation of the bottom echo in the transition field of the normal probe, calculations of frequency spectra and pulses for distances equal to 1 and 2 near field of the probe with a nominal frequency of 1.8 and 2.5 MHz were carried out. Calculations were carried out using the spectral density of the function describing the change in the complex amplitude of the bottom echo to the boundary of the near field of the probe. It is found that the change in the amplitude of the pulses at the maximum of the envelope for these distances varies almost the same as in the DGS-diagram of the bottom echo, while the difference in pulse shapes is not very significant. The results of the experiments generally confirmed the results of calculations taking into account the error of the initial data and the features of computer modeling.

Keywords: bottom echo, normal probe, piezoelectric plate, far field, near field, signal spectrum, pulse, DGS-diagram.

V. N. Danilov (JSC “RPA “CNIITMASH”, Moscow, Russia) E-mail: Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра.  

1. Ermolov I. N., Lange Yu. V. (2006). Ultrasonic inspection. Nondestructive testing: handbook: in 8 volumes. Vol. 3. 2nd ed. Moscow: Mashinostroenie. [in Russian language]
2. Ermolov I. N. (1992). Inspection with ultrasound: a quick handbook. Moscow: NPO TsNIITMASh. [in Russian language]
3. Ermolov I. N. (1981). Theory and practice of ultrasonic testing. Moscow: Mashinostroenie. [in Russian language]
4. Danilov V. N., Ermolov I. N. (1998). Change in the amplitude of the bottom signal with distance. Defektoskopiya, (5), pp. 57 – 63. [in Russian language]
5. Danilov V. N. (1985). Area of application of the formulas of the acoustic path of the flaw detector with a direct transducer. Defektoskopiya, (7), pp. 18 – 24. [in Russian language]
6. Yamshchikov V. S., Danilov V. N., Shkuratnik V. L. (1983). Peculiarities of excitation and reception of elastic waves in a solid layer by a piston-type transducer. Defektoskopiya, (3), pp. 16 – 23. [in Russian language]
7. Danilov V. N. (2006). Computer simulation program for the electroacoustic pathways defectoscopes "Impulse +". Defektoskopiya, (3), pp. 37 – 43. [in Russian language]
8. Danilov V. N., Izofatova N. Yu., Voronkov V. A. (1997). Comparison of theoretical and experimental results of direct coupled transducers. Defektoskopiya, (6), pp. 39 – 49. [in Russian language]
9. Danilov V. N. (2022). On the influence of the parameters of the electric excitation pulse of a piezoelectric plate of a normal probe on the characteristics of the frequency spectrum and pulse of the recorded echo signal. Kontrol'. Diagnostika, Vol. 25 (9), pp. 14 – 22. [in Russian language] DOI: 10.14489/td.2022.09.pp.014-022

This article  is available in electronic format (PDF).

The cost of a single article is 500 rubles. (including VAT 20%). After you place an order within a few days, you will receive following documents to your specified e-mail: account on payment and receipt to pay in the bank.

After depositing your payment on our bank account we send you file of the article by e-mail.

To order articles please copy the article doi:

10.14489/td.2023.06.pp.004-011

and fill out the  form  

 

 

 
Search
Rambler's Top100 Яндекс цитирования