Журнал Российского общества по неразрушающему контролю и технической диагностике
The journal of the Russian society for non-destructive testing and technical diagnostic
 
| Русский Русский | English English |
 
Главная Archive
26 | 12 | 2024
2016, 01 January

DOI: 10.14489/td.2016.01.pp.020-025

Efimov A.G., Shubockin A.E., Martyanov E.V., Mefodichev P.N.
EDDY-CURRENT NON-DESTRUCTIVE TESTING OF LARGE-DIAMETER PIPES
(pp. 20-25)

Abstract. The article deals with the metal-roll quality control issue. The eddy-current method of nondestructive testing has been compared with X-ray and ultrasonic methods which are usually used in metal-roll production. It is given the advantages of eddy current method for controlling the surface hardness of pipes. Conducted theoretical and experimental studies reveals that eddy current testing is the only nondestructive method allowing to indicate local problems of hardness through protecting and isolating coats. It has high sensitivity and control speed and should apply in final testing the quality of pipe production. Other methods do not allow to detect this type of defects. The validity of nondestructive control is significantly deteriorated without eddy current control in production of big diameter pipes. Described multichannel eddy current system for automated testing of pipes (VD-91NM) gives an opportunity to determine the surface cracks and areas of increased hardness through the protective coating of gas pipes for underwater sea crossings.

Keywords: non-destructive testing, eddy current testing, eddy current, local hardening, hardness control, microcracks, weld control, control of the pipe body.

A. G. Efimov, A. E. Shubockin, E. V. Martyanov, P. N. Mefodichev 
JSC RII “Spectrum”, Moscow, Russia. E-mail: Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра.  

1. Klyuev V. V. (Ed.), Muzhitskiy V. F., Gorkunov E. S. et al. (2010). Nondestructive Testing: Handbook: in 8 volumes. Vol. 1. In 3 books. Magnetic Testing, Eddy-current Testing, X-ray Testing. Moscow: Izdatel'skii dom «Spektr».

2. Fedosenko Iu. K., Shkatov P. N., Efimov A. G. (2011). Eddy current testing: textbook. Moscow: Izdatel'skii dom «Spektr».
3. Zagidulin R. V., Muzhitskii V. F., Efimov A. G. et al. (2007). Study of the effect of corrosion of the products on the main oil pipeline on eddy current flaw detector VD 12NFP signal. Kontrol'. Diagnostika, (9), pp. 42-46.
4. Efimov A. G. (2012). Influence of corrosion products and metal deposits on the detection of defects in the continuity of the electromagnetic testing of steel products. Part 1. Kontrol'. Diagnostika, (1), pp. 26-33.
5. Efimov A. G. (2012). Influence of corrosion products and metal deposits on the detection of defects in the continuity of the electromagnetic testing of steel products. Part 2. Kontrol'. Diagnostika, (2), pp. 25-33.
6. Efimov A. G. (2012). Eddy current probe signal distribution over steel products with an internal flaw in the applied magnetic field. Kontrol'. Diagnostika, (3), pp. 17-24.
7. Efimov A. G., Shubochkin A. E. (2014). Modern trends of eddy current flaw detection and defectometry. Kontrol'. Diagnostika, (3), pp. 68-73. doi: 10.14489/td.2014.03.pp.068-072.
8. Efimov A. G., Shubochkin A. E., Mart'ianov E. V. (2014). Modern eddy current flaw detection system for rolled steel. Kontrol'. Diagnostika, (12), pp. 19-21. doi: 10.14489/td.2014.12.pp.019-021.

This article  is available in electronic format (PDF).

The cost of a single article is 350 rubles. (including VAT 18%). After you place an order within a few days, you will receive following documents to your specified e-mail: account on payment and receipt to pay in the bank.

After depositing your payment on our bank account we send you file of the article by e-mail.

To order articles please fill out the form below:

Purchase digital version of a single article


Type the characters you see in the picture below



 

 

 
Search
Rambler's Top100 Яндекс цитирования