Журнал Российского общества по неразрушающему контролю и технической диагностике
The journal of the Russian society for non-destructive testing and technical diagnostic
 
| Русский Русский | English English |
 
Главная Archive
21 | 09 | 2026
2015, 09 September

DOI: 10.14489/td.2015.09.pp.052-059

 

Shilin A.N., Shilin A.A., Artyushenko N.S.
CALCULATION ERRORS OF REFLECTOMETERS FOR MONITORING POWER LINES
(pp. 052-059)

Abstract. From the analysis of accidents in the energy system of Russia follows that the most unreliable element of the energy system are overhead power lines. Therefore efficiency of fault location VLEP reduces downtime and thus improves the reliability index – availability factor or the probability of failure-free operation. Currently, the energy system has different tools for fault location (WMD). The most widely used devices whose operation is based on the location of the probe pulse on the controlled section of the line and on the measurement of the time delay of the reflected pulse from the accident site. Devices in this class designed to deal with normalized errors, satisfying the practical requirements. However, in the real fault location error may significantly exceed normalized due to the factors listed above. The article analyzes the sources of reflectometers errors. The main source of reflectometers error is the error of the phase of velocity pulse. The expressions for calculating the phase error rate in the deviations of the parameters of lines depending on the frequency were obtained. The study results help reasonably choose constructive parameters of the instrument.

Keywords: emergency modes overhead power lines, monitoring overhead power lines, line with distributed parameters, tools for fault location of overhead power lines, reflectometer.

 

A. N. Shilin, A. A. Shilin, N. S. Artyushenko
Volgograd StateTechnical University, Volgograd, Russia. E-mail: Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра.

 

 

1. Arzhannikov E. A., Chukhin A. M. (1998). Methods and devices for determining the fault location on the line: textbook. Ivanovo: Ivanovskii gosudarstvennyi energeticheskii universitet.
2. Blinov I. V., Parus E. V., Polishchuk E. Iu. (2013). Monitoring of overhead transmission lines using damage indicators. Elektroenergeticheskie sistemy i seti. (4), pp. 42-44.
3. Tarasov N. A. (2014). Status and prospects of im-pulse testing of power cable lines. Cable measuring equip-ment. Available at: http://reis105.narod.ru/article.htm. (Ac-cessed: 10.09.2014).
4. Bessonov A. A. (1978). Theoretical foundations of electrical engineering: Electrical circuits. Moscow: Vysshaia shkola.
5. The characteristic parameters of a long line. (2010). Radiolektorii. Available at: http://www.radioforall.ru/2010-01-19-08-09-28/597-2010-01-20-09-05-28. (Accessed: 06.04.2014).
6. Novitskii P. V., Zograf I. A. (1985). Assessment of uncertainties of measurement results. Leningrad: Energoatomizdat.

 

 

This article  is available in electronic format (PDF).

DOI: 10.14489/td.2015.09.pp.052-059

Copy the article DOI and follow the link https://id-spektr.ru/product/pokupka-elektronnoy-stati-iz-zhurnala-kontrol-diagnostika

Please specify the article DOI in the order comments.

 

 

 
Search