Журнал Российского общества по неразрушающему контролю и технической диагностике
The journal of the Russian society for non-destructive testing and technical diagnostic
 
| Русский Русский | English English |
 
Главная
23 | 12 | 2024
2014, 02 February

DOI: 10.14489/TD.2014.02.PP.015-023 


Chuprin V.A.

OPTIMIZATION OF ULTRASONIC DEVICE PARAMETERS FOR MEASUREMENTS OF LUBRICANTS VISCOSITY FOR IN-LINE CONDITION DIAGNOSTICS OF MACHINE EQUIPMENT. PART 1
(pp. 15-23)

Abstract. Part 1. Check of suitability of rheological model  
It is noted that actual viscosity of lubrication liquids is an important element of a complex of the information parameters regulated in ISO and reflecting a technical state of the diagnosed equipment. The reliability of the numerical values of shear viscosity found from ultrasonic measurements depends on a number of factors, most important of which are suitability of rheological model of the liquid on which the calculation of viscosity are based, compliance of the accepted in the analysis approximations influencing interaction of normal waves propagating in a waveguide immersed in a liquid to real measurement conditions, the integration possibility of ultrasonic waveguide impedance sensors in a design of the diagnosed equipment. The first of the listed factors is considered in the present article. Criteria of check of applicability of the Newtonian model of viscous liquids to real liquids are offered. Experimental researches are conducted on water solutions of glycerol with concentration of 0...100 % (viscosity of solutions changes from 0,01 to 10,00 Р) on three frequencies: 1,0; 1,7 and 2,5 MHz. It is established that in this frequency range the theory using Newton rheological model well describes the interaction of zero modes of normal waves with liquids till viscosity values up to 1 P. It is revealed that there are some frequency-independent distinctions between measured and tabular values of shear viscosity for very small viscous liquids. An explanation possibility of these distinctions is discussed by influence of roughnesses of a waveguide surface.

Keywords: diagnostics, ultrasonic measurements, horizontal-polarized normal plate wave, shear and kinematic viscosity, Newton rheological model, lubricant, water solutions of glycerol.

 

Chuprin V.A 
LLC «Scientific-Industrial Company «LUCH», Balashikha, Moscow region, Russia. E-mail: Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра.

 

 

 

 

 

 

 

 

 

 

1. Condition monitoring and diagnostics of machines. General guidelines on data interpretation and diagnostics techniques. (2012). Standard No. ISO 13379-2012.
2. Masian V., Tormos B., Sala A., Ramirez J. (2006). Fuzzy logic-based expert system for diesel engine oil analyses diagnosis. Insight, 48(8), pp. 462-469. doi: 10.1784/insi.2006.48.8.462
3. Mak-Skimin G., Mezon U. (Ed.). (1966). Ultrasonic methods of measurement of mechanical characteristics of liquids and solids. Physical acoustics. (Vol. 1, Part A), pp. 327-397). Moscow: Mir.
4. Ballantine D. S., White R. W., Ricco S. J. et al. (1997). Acoustic wave sensors. San Diego: Academic.
5. Lange K., Rapp B. E., Rapp M. (2008). Surface acoustical wave biosensors: a review. Anal. Bioanal. Chem., 391, pp. 1509-1519. doi: 10.1007/s00216-008-1911-5
6. Greenwood M. S., Adamson J. D., Bond L. J. (2006). Measurement of the viscosity-density product using multiple reflections of ultrasonic shear horizontal waves. Ultrasonics, 44, pp. 1031-1036. doi: 10.1016/j.ultras.2006.05.093
7. Lynnworth L. C. (1989). Ultrasonic measurements for process control: theory, technique, applications. Boston: Academic Press.
8. Vogt T. K., Lowe M. J. S., Cawley P. (2004). Measurements of the material properties of viscous liquids using ultrasonic guided waves. IEEE Transaction on Ultrasonics, Ferroelectrics and Frequency Control, 51(6), pp. 737-747. doi: 10.1109/TUFFC.2004.1304272
9. Gitis M. B., Chuprin V. A. (2012). Application of ultrasonic surface and the normal waves to measure parameters of technical liquids. 1. Measurement of shear viscosity. ZhTF, 82(5), pp. 93-99.
10. Gitis M. B., Chuprin V. A. (2012). Application of ultrasonic, surface and normal waves to measure parameters of technical liquids. 2. Density measurement. ZhTF, 82(5), pp. 100-105.
11. Chuprin V., Gitis M. (2012). Measurements of the Material Properties of Liquids Using Normal Acoustic Plate Waves. Proc. 18th World Confer. NDT. Durban.
12. Miker T., Meittsler A., Mezon U. (Ed.). (1966). Waveguide distribution in long cylinders and plates. Physical acoustics. (Vol. 1, Part A, pp. 140-203). Moscow: Mir.
13. Segur J. B., Oberstar H. (1951). Viscosity of glycerol and its aqueous solutions. Ind. & Eng. Chem., 43, pp. 2117-2120.
14. Chuprin V. A. (2013). Experimental research of the characteristics of the acoustic field of zero normal modes of oscillations of thin plates. Akusticheskii zhurnal, 59(1), pp. 122-133.
15. Landau L. D., Lifshits E. M. (1988). Hydrodynamics. Moscow: Nauka.
16. Shah V. V., Balasubramaniam K. (2000). Measuring newtonian viscosity from the phase of reflected ultrasonic shear wave. Ultrasonics, 38, 921-927. doi: 10.1016/S0041-624X(00)00033-0

 

 

This article  is available in electronic format (PDF).

The cost of a single article is 350 rubles. (including VAT 18%). After you place an order within a few days, you will receive following documents to your specified e-mail: account on payment and receipt to pay in the bank.

After depositing your payment on our bank account we send you file of the article by e-mail.

To order articles please fill out the form below:

Purchase digital version of a single article


Type the characters you see in the picture below



 

 

 

 

 

 

 
Rambler's Top100 Яндекс цитирования