Журнал Российского общества по неразрушающему контролю и технической диагностике
The journal of the Russian society for non-destructive testing and technical diagnostic
 
| Русский Русский | English English |
 
Главная
23 | 12 | 2024
2014, 07 July

DOI: 10.14489/td.2014.07.pp.039-051

 

Danilov V.N.
CALCULATION OF A BOTTOM ECHO FOR MODEL OF THE STRAIGHT BEAM TRANSDUCER WITH THE RECTANGULAR PHASED ARRAY
(pp. 39-51)

Abstract. The computer simulation of a bottom echo of the straight beam transducer with the rectangular phased array for two versions of a fo-cusing is conducted. The confrontation of outcomes of calculations of relation of change of normalized amplitude of a bottom echo of the transducer to the phased array from distance with usage of analytical expressions and straight lines by numerical toting of echoes in view of a focusing has shown their coincidence. Is established, that as against customary transducers, the change of the wave size of transducers with the phased arrays notably has an effect for value of amplitude of a bottom echo in a maximum. The influencing on relation of a base signal of a focusing on fixed distance is reviewed.

Keywords: straight beam transducer, rectangular phased array, bottom echo, full focusing, central focusing, wave number, near field, point of reflection, fixed distance of a focusing.

 

V. N. Danilov
PJSC RPA «CNIITMASH», Moscow, Russia. E-mail: Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра.  

 

 

1. Ermolov I. N. (1992). Ultrasound testing: quick ref-erence. Moscow: NPO TsNIITMASh.
2. Ermolov I. N., Lange Iu. V. (2004). Non-destructive testing. Handbook. In 8 volumes. Vol. 3. Ultrasonic testing. Moscow: Mashinostroenie.
3. Danilov V. N., Voronkov V. A. (2013). Modelling back-wall echo of a normal linear probe with the phased array. Kontrol'. Diagnostika, (7), pp. 27-34.
4. Danilov V. N. (2010). About some peculiarities of the signal of the direct linear converter with phased array in radiation mode. Defektoskopiia, (10), pp. 59-74.
5. Danilov V. N. (2011). The study of the model of the transducer with two-dimensional phased array in radiation mode. Defektoskopiia, (7), pp. 29-48.
6. Danilov V. N. (2009). Calculation of DGS(AVG) di-agrams of direct converter with rectangular pie-zoplate. Defektoskopiia, (11), pp. 22-40.
7. Danilov V. N. (2004). Calculation of the bottom sig-nal of direct converter with rectangular pie-zoplate. Defektoskopiia, (5), pp. 9-14.
8. Danilov V. N. (2004). Question about the calculation of an acoustic field of the direct converter with piezoplates of various forms. Defektoskopiia, (2), pp. 3-13.
9. Korn G., Korn T. (1974). Handbook on mathematics for scientists and engineers. Moscow: Nauka.
10. Danilov V. N. (2013). Simulation of the DGS-diagram of an angle transducer with a rectangular phased array. Kontrol'. Diagnostika, (12), pp. 9-16.
11. Danilov V. N., Voronkov I. V. (2010). Simulation of work of the direct converter with phased array in radiation mode. Defektoskopiia, (7), pp. 3-17.

 

 

This article  is available in electronic format (PDF).

The cost of a single article is 250 rubles. (including VAT 18%). After you place an order within a few days, you will receive following documents to your specified e-mail: account on payment and receipt to pay in the bank.

After depositing your payment on our bank account we send you file of the article by e-mail.

To order articles please fill out the form below:

Purchase digital version of a single article


Type the characters you see in the picture below



 

 

 

 

 

 
Rambler's Top100 Яндекс цитирования