Журнал Российского общества по неразрушающему контролю и технической диагностике
The journal of the Russian society for non-destructive testing and technical diagnostic
 
| Русский Русский | English English |
 
Главная
23 | 12 | 2024
2018, 05 May

DOI: 10.14489/td.2018.05.pp.054-056

 

Abdurahimov S. H.
POSSIBILITY DECREASING THE TEMPERATURE ERROR OF DIAGNOSTIC SYSTEMS
(pp. 54-56)

Abstract. Operative and accurate detection of location and time of occurrence and level of gravity of hydrocarbons leaks from main pipelines is an important task of SCADA type systems designated for gathering the diagnostics information and carrying out the control of condition of hydrocarbons transportation system. The occurrence of losses of hydrocarbons mass due to leaks at some part of pipeline leads to generation of acoustic signals used as a basis for detection of location, time and level of gravity of leaks. It is shown that in existing realizations of SCADA systems in regime of leaks detection the impact of temperature on accuracy of location is somewhat disregarded. The carried out analysis does show that if the interval of installation of temperature sensors prevails on interval of installation of acoustic sensors in regime of leaks location the temperature error of SCADA system may reach the significant value. The new order for selection of elements of pairs of measuring sensors used for determination of differences between the time intervals of reaching the acoustic signals of these sensors is suggested. According to the new order of sensors selection the both sensors of the pair should be located in left or in right of the leak point. The mathematical grounding of suggested method is given and decrease of temperature error is estimated.

Keywords: temperature error, acoustic waves, leaks, hydrocarbons, main pipelines, SCADA systems.

 

 S. H. Abdurahimov (Azerbaijan State University of Oil and Industry, Вaku, Azerbaijan) E-mail: Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра.

 

 

1. Turner W. J., Mudford N. R. (1988). Leak detection timing, location and sizing in gas pipelines. Mathl Comput. Modelling, 10(8), pp. 609-627.
2. Wan J., Yu Y., Wu Y. et al. (2012). Hierarchical leak detection and localization method in natural gas pipeline monitoring sensor networks. Sensors, 12(1), pp. 189-214. doi: 10.3390/s120100189.

 

 

This article  is available in electronic format (PDF).

The cost of a single article is 350 rubles. (including VAT 18%). After you place an order within a few days, you will receive following documents to your specified e-mail: account on payment and receipt to pay in the bank.

After depositing your payment on our bank account we send you file of the article by e-mail.

To order articles please copy the article doi:

10.14489/td.2018.05.pp.054-056

and fill out the  form  

 

 

 
Rambler's Top100 Яндекс цитирования