Журнал Российского общества по неразрушающему контролю и технической диагностике
The journal of the Russian society for non-destructive testing and technical diagnostic
 
| Русский Русский | English English |
 
Главная
23 | 10 | 2026
Баннер
2016, 02 February

DOI: 10.14489/td.2016.02.pp.051-054 

Karkin I.N.
THE TECHNIQUE OF USING MOBILE COERCIMETERS FOR PERIODIC STRUCTURAL HEALTH MONITORING
(pp. 51-54)

Abstract. Completely new portable coercimeter-structurescope KSP-01 was developed nearly 50 years after the creation of the first coercimetersof KIFM series. The key features of the new device from the predecessors are its compactness, autonomy and mobility, as well as the presence of a wireless communication interface bluetooth, which allows you to use the device with communicators based on OS-Android. The article describes the technique of using coercimeter to solve the problem of mobile-periods monitoring potentially dangerous objects. In addition, it is given examples of replaceable tips of coercimeter sensor for non-destructive control objects of complex shapes.

Keywords: coercimeter, coercive force, nondestructive testing.

 

I. N. Karkin
“NPP Strukturnaya Diagnostika” Ltd, Ekaterinburg, Russia. E-mail: Данный адрес e-mail защищен от спам-ботов, Вам необходимо включить Javascript для его просмотра.  

 

1. Mikheev M. N. (1940). Magnetic testing method of heat treatment of tractor products. Vestnik metallopromyshlennosti, (8/9), pp. 87-89.
2. Förster F. (1955). Ein Betriebsgerat zur schnellen und genauen Messung der Koerzitivkraft sowie ihrer Temperaturabhägigkeit. Ztschr. Metalk, 46(4), pp. 297-302.
3. Mikheev M. N. (1941). Universal portable coercimeter for quality testing of the heat treatment of steel products. Trudy instituta metallovedeniia, metallurgii i metallofiziki, (1), pp. 1-10.
4. Gorkunov E. S., Zakharov V. A. (1995). Coercimeters with auxiliary magnetic devices (review). Defektoskopiia, (8), pp. 69-88.
5. Bida G. V., Nichipuruk A. P. (2000). Coercive force measurements in nondestructive testing. Defektoskopiia, (10), pp. 3-28. (Bida G. V., Nichipuruk A. P. (2000). Coercive force measurements in nondestructive testing. Russian Journal of Nondestructive Testing, 36(10), pp. 707-727.)
6. Murikov S. A., Artem'ev I. A., Murikov E. S. et al. (2011). Possibilities of coercimetry to diagnose the technical condition of the hot rolling mill rollers. Stal', (11), pp. 68-71.

 

 

This article  is available in electronic format (PDF).

DOI: 10.14489/td.2016.02.pp.051-054

Copy the article DOI and follow the link https://id-spektr.ru/product/pokupka-elektronnoy-stati-iz-zhurnala-kontrol-diagnostika

Please specify the article DOI in the order comments.